    Description

    Ю116 Meter (S-116, S 116)
    For measuring illumination generated by incandescent and natural light sources which are arbitrarily located relative to the light receiver of the light meter.
    The dial pointer.
    Measuring range from 5 to 100000 lx.
    The power of energy light.
    Dimensions 210х125х85мм, weight 0.85 kg.
    Ю116 meter is designed for measuring illumination generated by incandescent and natural light sources which are arbitrarily located relative to the light receiver of the light meter.
    Portable photoelectric light meter Ю116 General purpose is used to control the light in industry, agriculture, transport and other sectors of the economy and also for research in science, engineering and design organizations.
    Type of climatic performance of the device Luxmeters Ю116 - category 3.1 according to GOST 15I50-69 but for working temperatures from minus 10 to plus 35 °C to a relative humidity of 80% at 20° C.
    Technical data
    The measuring range and the total par attenuation coefficient used two nozzles are shown in table.1 and note to table.1.
    Диапазон измерений, лк
    основной
    Неосновной
    без насадок, с открытым фотоэлементом
    с насадками
    КМ
    КР
    КТ
    5лк-30лк
    50лк-300лк
    500лк-3000лк
    5000лк-30000лк
    20лк-100лк
    200лк-1000лк
    2000лк-10000лк
    20000лк-100000лк
    Note. KM, KR, KT is the symbol of nozzles used together to create a total nominal attenuation of 10, 100, 1000 respectively .
    The scale of the instrument Meter Ю116 uneven, graded suites: one scale has 100 divisions, the second 30 points.
    Mark "5" dial 0-30, mark "20" scale 0-100, corresponding to the initial values of the ranges marked accurately.
    The limits of permissible error of the meter is basically measuring range 5лк-30лк and 20лк-100лк (without attachments) should not exceed ±10% of the value of the measured light.
    Permissible change of meter readings caused deviation of ambient temperature from 20 °C to any temperature in the range from minus 10 to plus 35 °C does not exceed ±1% of measured value per 1 °C.
    Overall dimensions of the instrument Meter Ю116:
    210х125х85мм - meter meter;
    185 x 105 x 55mm - photocell light meter, with attachments KM, or CU, OR CT scan;
    300 x 155 x 135 - case of the meter.
    Weight of the device Meter Ю116 not more than: 0,85 kg without case; 1.75 kg - in box.